whatsapp: 0086-15153112822
Fluid Mechanics Experiment Equipment

Separation In Sedimentation Tanks Didactic Equipment School Equipment Teaching Fluid Mechanics Laboratory Equipment

Item No.: HM 142
HM 142 Separation In Sedimentation Tanks Didactic Equipment School Equipment Teaching Fluid Mechanics Laboratory Equipment
Request Quote
Description
HM 142 Separation In Sedimentation Tanks Didactic Equipment School Equipment Teaching Fluid Mechanics Laboratory Equipment
Description
In sedimentation tanks, solids are separated out from suspensions under the influence of gravity. In this process the density of the solid particles must be greater than that of the liquid. HM 142 makes it possible to investigate the separation of solids from a suspension in a sedimentation tank.


First a concentrated suspension is prepared in a tank, comprising water and the solid to be separated. A pump transports the concentrated suspension to the sedimentation tank. Upstream of the sedimentation tank the suspension is mixed with fresh water. The raw water generated in this way flows into the sedimentation tank via an inlet weir. A stirring machine is located upstream of the inlet weir. This prevents solids sedimenting before entering the sedimentation tank. The treated water first flows under a baffle and then over a weir to the outlet.

The height of the weir on the outlet side is adjustable and allows the water level in the sedimentation tank to be changed. The water level above the inlet weir can also be adjusted. This affects the flow velocity over the inlet weir.
A lamella unit can be inserted into the experimental section. This makes it possible to study how lamellas affect the separation process. The flow through the lamellas occurs from bottom to top. Above the lamellas is an outlet channel. The side walls of the outlet channel are designed as a serrated weir.

The flow rates of the concentrated suspension and the fresh water are adjusted via valves. This means the mixing ratio, and thus the concentration of solids in the inlet to the sedimentation tank, can be adjusted. An electromagnetic flow rate sensor measures the flow rate in the inlet of the sedimentation tank. Flow rate and speed of the stirring machine are displayed digitally. The sedimentation tank is equipped with lighting to better observe the flow conditions.

Technical details
Specification
separation of suspensions by sedimentation in the sedimentation tank
transparent sedimentation tank with lighting for visualisation of the flow conditions
stirring machine in the inlet area of the sedimentation tank
lamella unit can optionally be inserted into the sedimentation tank
tank with pump and stirring machine to create and transport a concentrated suspension
mixture of the concentrated suspension with fresh water gives the raw water to be studied
adjustment of the concentration of solids via valves for fresh water flow rate and suspension flow rate
adjustable water level in the sedimentation tank and adjustable flow velocity in the inlet
electromagnetic flow rate sensor for raw water
Imhoff cones for determining settleable substances of a water sample


Technical data
Sedimentation tank (experimental section)
LxWxH: 900x110x300mm
max. filling capacity: approx. 25L
material: plexiglass
Lamella unit
angle of inclination of lamellas: 60°
number of lamellas: 16
Suspension tank
capacity: approx. 85L
material: stainless steel
Pump
max. flow rate: 75L/h
Stirring machines (max. speed)
suspension tank: 600min-1
sedimentation tank: 330min-1


Measuring ranges
flow rate: 30…600L/h
230V, 50Hz, 1 phase
230V, 60Hz, 1 phase; 120V, 60Hz, 1 phase