HM 168 Sediment Transport In River Courses Teaching Equipment Lab Equipment Prices Fluid Mechanics Laboratory Equipment
HM 168 demonstrates important phenomena of bed-load transport in the area near the bottom at subcritical discharge. The large dimensions of the experimental section enable the modelling of river courses with and without structure.
The core element of the HM 168 experimental flume is the stainless steel experimental section. A sediment layer up to 10cm high covering an area of 5x0,8m allows bed-load transport to be studied. The sediment is held in the experimental section by plate weirs at the inlet and at the outlet. The tank after the water drain contains a sediment trap with a filter element for sand. The water circuit is closed.


In addition to bed-load transport in open channels without structures, some models can also be used to observe fluvial obstacle marks, namely scour formation and siltation at structures. A bridge pier, a plate weir or an island can be inserted into the experimental section. You can also design your own models using deflection plates and angular steel.
Profile measurement in the sediment along the bottom and the determination of the discharge depth at each point on the experimental section is done via a movable instrument carrier and a point gauge. The discharge is measured via an electromagnetic flow meter.


Technical details
Specification
open-channel bed-load transport
experimental flume with experimental section, inlet element, outlet element, closed water circuit, 1 set of models
closed water circuit with water tank with sediment trap, pump, and electromagnetic flow meter
experimental section with grooves for plate weirs to realise different flow conditions
measurement of profiles along the bottom with moveable instrument carrier and point gauge
inlet element with plate weir to protect against sediment flowing back
models supplied 3 bridge piers, 2 islands, set of deflection plates (for your own model ideas)
sediment trap with filter element for sand
experimental section, inlet and outlet element made of stainless steel


Technical data
Experimental flume
stainless steel
dimensions of the experimental section: 5000x800x250mm


Pump
power consumption: 2,2kW
max. head: 11,5m
max. flow rate: 74m3/h
Storage tank, content: approx. 1000L
Sediment trap filter element
aperture size: 0,3mm (49mesh)
Flow meter
measuring range: 80m3/h
400V, 50Hz, 3 phases
400V, 60Hz, 3 phases; 230V, 60Hz, 3 phases